Documentation
LiveWireLiveWire Core 1300 Quick Start GuideDownload PDF
LiveWire Core 1300 : LiveWire Core 1300 Technical Specifications
LiveWire Core 1300 Technical Specifications
Specification
Description
Base
OEM PowerEdge R6615 Server
Chassis
2.5" Chassis with up to 10 Hot Plug Hard Drives
Motherboard
PowerEdge R6615 Motherboard
Processor
AMD 9254 2.9GHz 24C/48T (1)
Memory
32GB RDIMM, 5600MT/s, Dual Rank (4)
RAID/Internal Storage Controllers
PERC H755 SAS, Front
Hard Drive
BOSS-N1 controller card + with 2 M.2 960GB (RAID 1)
2.4TB Hard Drive SAS ISE 12Gbps 10K 512e (10)
Network Adapters
Broadcom 5720 Dual Port 1GbE LOM
Broadcom 57416 Dual Port 10GbE BASE-T Adapter, OCP NIC 3.0
Fans
Very High Performance Fan x4
Power Supply
Dual, Hot Plug, Redundant Power Supply (1+1), 1100W
Power Cords
C13 to C14, PDU Style, 12 AMP, 6.5 Feet (2m) Power Cord, North America
PCIe Riser
Riser Config 3, 2 x 16 FH
Embedded Systems Management
iDRAC9, Enterprise
Quick Sync
None
Rack Rails
ReadyRails Sliding Rails Without Cable Management Arm
PSU Specifications:
 PSU
 Class
 Heat Dissipation (Maximum)
 Frequency
 Voltage
 Current
 
1100W Mixed Mode
Titanium
4100 BTU/hr
50/60 Hz
100–240 V AC, autoranging
12 - 6.3 A
Temperature Specifications ASHRAE A2:
 Allowable continuous operations
 
 Temperature range for altitudes <= 900 m (<= 2953 ft)
10 to 35°C (50 to 95°F) with no direct sunlight on the platform
 Humidity percent range (non-condensing at all times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point
 Operational altitude de-rating
Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900 m (2953 Ft)
Temperature Specifications ASHRAE A3:
 Allowable continuous operations
 
 Temperature range for altitudes <= 900 m (<= 2953 ft)
5 to 40°C (41 to 104°F) with no direct sunlight on the equipment
 Humidity percent range (non-condensing at all times)
8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point
 Operational altitude de-rating
Maximum temperature is reduced by 1°C/175 m (1.8°F/574 Ft) above 900 m (2953 Ft)
Temperature Specifications ASHRAE A4:
 Allowable continuous operations
 
 Temperature range for altitudes <= 900 m (<= 2953 ft)
5 to 45°C (41 to 113°F) with no direct sunlight on the equipment
 Humidity percent range (non-condensing at all times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point
 Operational altitude de-rating
Maximum temperature is reduced by 1°C/125 m (1.8°F/410 Ft) above 900 m (2953 Ft)
Common Environmental Specifications:
 
 Maximum temperature gradient (applies to both operation and non-operation)
20°C in an hour* (36°F in an hour) and 5°C in 15 minutes (9°F in 15 minutes), 5°C in an hour* (9°F in an hour) for tape hardware
 
NOTE:* - Per ASHRAE thermal guidelines for tape hardware, these are not instantaneous rates of temperature change.
 Non-operational temperature limits
-40 to 65°C (-40 to 149°F)
 Non-operational humidity limits
5% to 95% RH with 27°C (80.6°F) maximum dew point
 Maximum non-operational altitude
12,000 meters (39,370 feet)
 Maximum operational altitude
3,050 meters (10,006 feet)
Maximum Vibration Specifications:
 
 Operating
0.21 Grms at 5 Hz to 500 Hz for 10 minutes (all operation orientations)
 Storage
1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Maximum Shock Pulse Specifications:
 
 Operating
Six consecutively executed shock pulses in the positive and negative x, y, and z axis of 6 G for up to 11 ms
 Storage
Six consecutively executed shock pulses in the positive and negative x, y, and z axis (one pulse on each side of the system) of 71 G for up to 2 ms